IBD Isolator & Bonding Device

Description
Specifications

Designed to provide depot road isolation and interlocked negative bonding of conductor rails at Various Main Line Depots. The manual handles are interlocked so that the Isolator cannot be closed at the same time as the Bonding Switch.

Applications:
Switchgear Enclosures (SE),

Approvals:
NR approved,

Key Features

  • 100mm electrical clearance
  • padlock facilities
On / Off load On Load
System Voltage 750V
Normal Current 2000A
Peak Current 10000A
Withstand Current 6000A
Short Circuit Capacity 66000A
Length 1100mm
Depth 540mm
Height 1560mm